The surface of an electrode is rarely, if ever, a homogenous surface.  It is often incorrectly assumed to be in order to simplify data interpretation and mathematical modeling.  However, a corroding metal will certainly have areas of both anodic and cathodic nature, and a sensor will have areas of varying surface conductivity.

In a traditional bulk electrochemical measurement, the current from the entire working electrode is recorded.  This gives an integrated response.  It is then impossible to distinguish if the sample has a uniform response distributed evenly about its surface; or a small number of sites of much greater intensity.

The M370 consists of an advanced three-dimensional closed-loop (100-nm resolution) positioning system mounted onto an optical base.  Depending on the ancillary equipment mounted onto or connected to this positioning system, the M370 can provide a breadth of information.  As different as each of the techniques is, they have the common goal of providing localized information relative to the sample under investigation.

In general, this is accomplished by using this advanced positioning system to bring a measurement probe to within 10s-100s of microns of the sample’s surface, without actually contacting it.  When the measurement probe is within this dimension it only samples the response of the local area, not the entire electrode’s surface.  The probe is then rastered across the plane above the sample.  This builds a 3-dimensional map – with the X and Y being displacement of the probe and the third axis as the measured parameter (e.g., current in a SECM experiment, voltage-field in a SVP experiment, work function different in SKP, etc.)

The Princeton Applied Research M370 Scanning Electrochemical Workstation is capable of performing the following techniques using a single scanning base –

Scanning Electrochemical Microscopy (SECM) is the most popular scanning electrochemical technique.  Two (2) potentiostats are supplied to both control and measure the response of the ultramicroelectrode probe tip and the sample.  SECM is unique in its high spatial resolution and application to diverse fields, including fundamental research on reaction rates, biological system, sensors, etc.  The SECM uses Approach Curves to assist in positioning the probe and can image the surface in either Feedback or Generator-Collector Mode.  Constant-Height and Constant-Current experiments are supplied and Constant-Distance experiments are possible in combination with the OSP module, which is described below.  The supplied potentiostats can be used for a number of standard non-scanning experiments when not in use as a SECM.

Scanning Vibrating Probe (SVP/SVET) is the successor to the Scanning Reference Electrode Technique (SRET).  The goal of this experiment is to map local current events at the sample’s surface.  This is accomplished by measuring the voltage-drop created by those local currents in the electrolyte solution.  A piezo element controls the vibration to a user-specified amplitude.  The local current activity can be externally applied or naturally occurring.  Since the probe is vibrating, a lock-in amplifier is employed to enhance signal recovery allowing for the accurate measurement of small signals.

Localized Electrochemical Impedance Spectroscopy (LEIS) is similar to SVP; however, the AC-nature is not a mechanical probe vibration, but an AC voltage signal imposed onto the sample by external EIS-compatible instrumentation.  The resulting current is measured as a voltage-drop in solution using a dual-element probe.  This experiment can acquire data at a swept frequency and constant probe position (providing a Bode and Nyqusit plot) or at a single frequency and swept probe position providing an area map.  Magnitude, phase, voltage and current are recorded versus position in a single scan.  Experiments can be easily looped to monitor how the response changes with time.

Scanning Kelvin Probe (SKP) is a non-electrochemical non-destructive method, typically ran in the absence of electrolyte.  The goal of this measurement is to determine the relative work function difference between the sample and the probe.  The sample should be conducting, but can have an insulating or semi-conducting coating on it.  There are applications to the field of corrosion with the ability to image the surface under a coating and the ability to map work-function (a value relatable to Ecorr) in a non-destructive way; as well as applications to semi-conductors and the forensic sciences.

Scanning Droplet System (SDS) uses a machined head to move a constantly flowing droplet across the surface of the sample.  The exposed working area of the electrode is only that portion in contact with the droplet of electrolyte.  The flowing nature of the droplet removes reaction products as they are formed.  Standard electrochemical tests are then possible in confined, local areas on the sample’s surface.

Non-contact Surface Profiler (OSP) uses a laser to measure topography of the surface of the sample.  While there are many applications where topography is the end-goal, this becomes even more useful when used as a background file to run other techniques in Height-Tracking mode (e.g., constant-distance SECM).  This provides a mechanism to deconvolute effects that changing probe-to-sample distance may have on the response of other scanning techniques.

In addition to these techniques, there are several accessories that assist in sample mounting, probe positioning, and data presentation:

  • Environmental Tricell is a large 1-liter cell with circulation ports and a rubber gaiter for testing in other than ambient conditions.  Thumb-screws assist in leveling the sample.
  • The Micro-Tricell has a much smaller volume (~7 mL).  The Micro-Tricell was specifically designed for use with the SECM, but users also appreciate its flexibility in handling non-standard samples.
  • The VCAM3 is a long working distance microscope with LCD display that assists in positioning the probe over the sample.
  • Isoplot is a 3-Dimensional graphing tool for data presentation.

Each M370 system is professionally installed at on-site and verified with supplied test samples.  This personal interaction dramatically decreases the amount of time invested before your lab is up and running by increasing the confidence of the users.  Princeton Applied Research continues as the global leader in electrochemical instrumentation by supplying the most versatile scanning electrochemical system in the market.

上一个:传感器

下一个:研究电化学

华东地区(上海总部)

联系地址:上海外高桥富特东三路526号1幢二层

联系电话:021-58685111-AMT SI,4008353166转1

华北地区(北京)

联系地址:北京市朝阳区酒仙桥路10号京东方大厦二层西侧

联系电话:010-85262111-15, 4008353166转1

西北西南地区(成都)

联系地址:成都市锦悦西路160号高新孵化园9号楼F座10楼9-10号

联系电话:028-8675811-AMT SI,4008353166转1

华中华南地区(广州)

联系地址:广州市越秀区东风东路767号东宝大厦810室

联系电话:020-83634768-AMT SI,4008353166转1

北京维修中心

联系地址:北京市朝阳区酒仙桥路10号京东方大厦二层西侧

联系电话:010-85262111-12,186 0067 3523

投诉电话

联系地址:北京市朝阳区酒仙桥路10号京东方大厦二层西侧

联系电话:010-85262111-15,138 1746 0237

销售热线:
400 8353 166 -1

服务热线:
400 8353 199

邮箱:
amt.si.china@ametek.com